Ni Opc Server 2012 Serial Number
To activate your SSP you must use the Serial Number or Service ID associated with your NI Software. If you are a member of the NI Multi-Seat License Program, you will need to locate your Service ID. Organizations that have purchased a NI Multi-Seat License Program will designate a software administrator to oversee the management. KEPServerEX is more than an OPC server—it's a connectivity platform for industrial automation and IoT. Simply download KEPServerEX, and then select from Kepware's library of more than 150 device drivers, client drivers, and advanced plug-ins to fit the communication requirements unique to. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 如果您不能访问OPC Server,带有OPC 接口的National Instruments Industrial Automation Servers提供了很多协议的OPC 接口,其中包括Modbus。. Hello everyone, i have a SIMATIC s7-1200 PLC and i need to read-write the PLC tags through LabVIEW 2011. I am using NI OPC Server 2012 and Siemens TCP/IP Driver which supports s71200. Siemens driver is working correctly on my system (Windows 7 Ultimate) and i can read PLC tags with no problem. Unlike other Modbus to OPC interfaces, the OPC Server for Modbus can grant and deny access to tags based on user login. The Modbus OPC Server is a powerful tool that enables a secure access to your Control and Automation systems and opens new connectivity horizons to other parties and it is available at an unbeatable price.
Volume Serial Number Editor
Volume Serial Number Editor allows you to modify your disk drive's volume serial number (not hard disk's physical serial number which you can find at back of your hard disk) without reformatting your hard drive. Volume Serial Number Editor supports NTFS, FAT and FAT32 file system.
- Publisher: KRyLack Software
- Home page:www.krylack.com
- Last updated: December 6th, 2012
Disk Serial Number Changer
Disk Volume Serial Number Changer is a program that can change the serial number of any hard drive. It will NOT change the physical serial of your hard disk, just the internal number that the operating system applies to it. This can be useful when you try to install programs that take the serial number of your hard disk as a reference.
- Publisher: Keylack Software
- Home page:www.keylack.com
- Last updated: September 20th, 2011
Drive Serial Number Editor
Drive Serial Number Editor can modify your disk drive's Volume Serial Number (not hard disk's physical serial which you can find at back of your hard disk. Drive Volume Serial Number Editor has been released with improvements and fixes.System RequirementsWindows 98/NT/2000/XP/2003/Vista/7
- Publisher: KLLabs
- Home page:www.kllabs.com
- Last updated: August 18th, 2010
MatrikonOPC Funnel
MatrikonOPC Funnel provides a single gateway to all your process data. Now your applications only have to make one simple connection to access all of your plant data.Features include:-Supports aliases: rename tags with useful descriptions to make it easier to configure clients-Perform simple calculations for a specific point
- Publisher: Matrikon Inc.
- Home page:www.matrikonopc.com
- Last updated: November 21st, 2011
PI OPC (OPCInt) ICU Control
The PI OPC Interface is an OPC DA COM Interface for bidirectional communication between an OPC Data Access (DA) Server that supports v1.0a and 2.05 of OPC DA standard and an OSIsoft PI System.The PI OPC Interface collects data from OPC servers via the DA (Data Access) standard and writes them to the PI Server. It interoperates with any OPC Server.
- Publisher: OSIsoft, Inc.
- Last updated: July 16th, 2012
OPC Server Toolkit Demo
OPC Server Toolkit lets the programmer to create robust and highly effective OPC Servers within the shortest possible time. This toolkit eliminates the necessity of implementing all of the numerous OPC interfaces and COM programming.Toolkit can be used with any development environment supporting C++ language and dynamic linking.
- Publisher: Graybox Software
- Home page:www.gray-box.net
- Last updated: January 2nd, 2015
OPCEX Scheduler
The developer changed the name of the software in 'OPCEx Excel Add-In '. Provides an easy way to access real-time data originating from any OLE for Process Control (OPC) server. OPCEx makes it easy to provide OPC data to Excel workbooks. OPCEx supports OPC Data Access Standards 1.0 and 2.0. OPCEx allows end users to browse, add, read and write OPC data items via Microsoft Excel.
- Publisher: Resolvica, Inc.
- Home page:www.resolvica.com
- Last updated: December 19th, 2008
RadioLinx OPC Server
RadioLinx OPC Server is a program that seamlessly links customer applications to RadioLinx radios. It will allow any application that can act as an OPC Client, such as an HMI, to interact with most RadioLinx radios to get signal strength, serial number, limited throughput information as well as other useful statistics.
- Publisher: ProSoft Technology
- Home page:www.prosoft-technology.com
- Last updated: May 29th, 2013
Folder Lock
If in search of a comprehensive solution to protect all your sensitive information from prying eyes, Folder Lock offers you not only strong password protection and encryption, but also an unassailable backup to recover your lockers and wallets in case of data loss. It can protect both your system drives and whatever USB devices you wish to carry with you.
- Publisher: NewSoftwares LLC
- Home page:www.newsoftwares.net
- Last updated: August 19th, 2020
HD Tune
HD Tune 2.54 is a utility to measure your hard disks´ performance.It shows detailed information about the health status, errors and temperature of your hard disks.It also works with other storage devices such as memory cards, USB sticks, iPods, etc.
- Publisher: EFD Software
- Home page:www.hdtune.com
- Last updated: July 6th, 2020
Lenovo Service Bridge
The current set of capabilities include the following features: automatically detect your machine's serial number and machine type - model. This information is then passed to the main website so that the user is better assisted with support. This replaces the need to search or browse for your product when you need support.
- Publisher: Lenovo
- Last updated: November 18th, 2020
Serial Key Generator
Serial Key Generator is a program to help developers generate serial numbers for applications. You can generate serial keys using a custom number of columns and characters per column. The sequence of numbers/digits can be defined in the application. The output can be saved as CSV or TXT documents.
- Publisher: VCL Examples
- Home page:skgenerator.vclexamples.com
- Last updated: September 3rd, 2014
ALZip
ALZip offers you a very simple and easy way to manage archive files, such as ZIP files. While the program can create archives in 8 formats – including ZIP, TAR and JAR – it can open archives in more than 40 popular formats, including RAR, 7Z, ACE, CAB, ISO, and many more. That's why ALZip can perfectly replace any major archive file manager, like WinZIP or WinRAR.
- Publisher: ESTsoft Corp.
- Last updated: December 5th, 2011
Data Lifeguard Diagnostic for Windows
This program allows you to perform different tests and obtain information about your Western Digital drives from your Windows desktop. You can perform a quick or an extended test to detect and prevent drive failures. Also, you can obtain data about your drive, such as serial number, capacity, model, and so on.
- Publisher: Western Digital Corporation
- Home page:support.wdc.com
- Last updated: November 23rd, 2015
TOSHIBA Battery Check Utility
TOSHIBA Battery Check Utility is a free-to-use application for Windows OS that allows you to check if your battery pack is affected and qualifies for a replacement. Please Remove the battery and find the battery part number and serial number. The app is very easy-to-use.
- Publisher: TOSHIBA Corporation
- Last updated: December 19th, 2016
Recover Keys
Recover Keys is a simple program for finding and backing-up the installation keys of software applications. It quickly analyzes your system for over 10,000 software programs and produces a list of software activation keys. You can save, backup, print, or export (Word, Excel, PDF, HTML, CSV, XML) the license information.
- Publisher: ONE UP LTD.
- Home page:www.recover-keys.com
- Last updated: September 28th, 2015
PonyProg2000
Ponyprog is very powerful and popular microchip programmer. Ponyprog enables the user to program EEPROM, FLASH and PIC's using user friendly tools and multiple programmer types.Ponyprog supports AVR, SPI eeprom, AVR micro, 12C bus 8bit eeprom, PIC 16 micro, PIC 12 micro, AT89S micro and SDE2506 eeprom family chips.
- Publisher: Claudio Lanconelli
- Last updated: August 2nd, 2017
MiniTool Partition Wizard
MiniTool Partition Wizard allows you to create, move, resize, and delete hard disk partitions. It can also help you convert FAT file system to NTFS, make an exact copy of a volume, and wipe partitions to prevent data recovery. Merging of partitions can also be done, without losing data.
- Publisher: MiniTool Solution Ltd.
- Home page:www.partitionwizard.com
- Last updated: August 19th, 2020
Ni Opc Ua
Table of contents:
1 Introduction
2 Configuring I/O channels in Measurement & Automation Explorer (MAX)
3 Renaming I/O channels
4 Testing I/O channels
5 Using FieldPoint I/O in LabVIEW
5.1 Introduction
5.2 Using FieldPoint functions for I/O operations
5.3 Using OPC for I/O operations
1 Introduction
FieldPoint is a distributed modular I/O system produced by National Instruments. FieldPoint can be used with e.g. LabVIEW. If the FieldPoint hardware is equipped with an RT (Real-Time) module containing an embedded controller (microprocessor) running LabVIEW RT, you can download and run LabVIEW programs on the FieldPoint device. This document does not cover using FieldPoint for such embedded control.
Figure 1 below shows the FieldPoint rack at TechTeach's disposal. (National Instruments also delivers Compact FieldPoint which is a more recent product, but with similar capabilities as the original FieldPoint system.)
Ni Opc Server 2012 Serial Number Decoder
Figure 1: FieldPoint I/O system
The rack shown in Figure 1 contains the following modules:
- Network module FP1000 with a terminal for serial connection to a PC via RS232 serial cable. A DC power supply delivering a DC voltage between 12V and 24V, e.g. 24V, must be connected to the V and C terminals. The FP1000 module does not contain a micro processor, only AD- and DA converters and electronics implementing the serial communication. Thus the FP1000 module is not for embedded control. In stead, the application program must be implemented in LabVIEW.
- Terminal base module FP TB10 containing the following six dual channel modules (each of these modules has two channels):
- AO (analog output) module for voltage output in the range +/- 10V
- Pt100 module for connecting Pt100 temperature sensors (these sensor are not shown in the figure)
- AO module for current output in the range 0 - 20mA
- AI module (analog input) for voltage input in the range +/- 10V
- DI (digital input) module
- DO (digital output) module
[Table of contents]
2 Configuring I/O channels in Measurement & Automation Explorer (MAX)
Before using the Fieldpoint I/O channels in LabVIEW, you must configure the I/O channels (and you should also test the channels) - using the Measurement & Automation Explorer (MAX) utility which is available via Start / Programs / National Instruments. (From FieldPoint 4.0 configuration of Fieldpoint is done using MAX, while this was previously done using the FieldPoint Explorer.)
Help about using MAX for configuring and testing FieldPoint is described in detail in the FieldPoint help in MAX. Go to Help / Help Topics / FieldPoint in MAX.
Figure 2 shows the dialog window where you configure the channels. As seen in the figure, this dialog window is available via My System / Devices and Interfaces in MAX.
Figure 2: Dialog window for configuring I/O channels in MAX
https://cleverjava.weebly.com/blog/download-visual-box-for-mac. The configurations can be saved in a *.iak file via the menu Tools / FieldPoint / Save in MAX.
[Table of contents]
3 Renaming I/O channels
Figure 3 shows the dialog window where you can rename I/O channels. This dialog window is available via My System / Date Neighborhood.
Figure 3: Dialog window for renaming I/O channels in MAX
[Table of contents]
4 Testing I/O channels
Figure 4 shows the dialog window where you can test I/O channels. This dialog window is available via My System / Date Neighborhood. You start monitoring I/O channel values (e.g. voltage values) by clicking the Start button, and you can write output values (e.g. a voltage for an analog output channel) by clicking the Write button. (Tip: A very simple way of testing that both analog output and analog input works correctly, is by connecting the input to the output.) /tib-files-convert-to-iso.html.
Figure 4: Dialog window for renaming and testing I/O channels in MAX
Ni Opc Server 2018
[Table of contents]
5 Using FieldPoint I/O in LabVIEW
5.1 Introduction
The I/O channels defined in FieldPoint Explorer can be used in your LabVIEW program (a VI) in two alternative ways:
- Using in-built FieldPoint functions available on the Functions palette in LabVIEW
- Using OPC (OLE for Process Control)
Both methods are described in the following. The methods are equally simple to use. Using FieldPoint functions may give faster data transfer, while OPC is more flexible since other software than LabVIEW can be used to address the FieldPoint I/O channels.
[Table of contents]
5.2 Using FieldPoint functions for I/O operations
The FieldPoint functions are available at the NI Measurements subpalette on the Functions palette, see Figure 5.
Figure 5: FieldPoint functions are available at the NI Measurements subpalette on the Functions palette
Figure 6 shows the front panel and Figure 7 shows the block diagram ofiotest_fp_functions.vi where the FieldPoint functions FP Write and FP Read are used. (Alternatively, you can use the FieldPoint Express function available down left, and also the FP WriteRead function, for both Write and Read operations.) The Type input to the FP Read function is used to define the data type (here double floating point number).
Figure 6: Front panel ofiotest_fp_functions.vi
Figure 7: Block diagram ofiotest_fp_functions.vi
The I/O FieldPoint constants in the block diagram in Figure 7 (the wide magenta rectangulars) contains at the right a browse button which you can use to browse to the FieldPoint I/O channel (or item or point), see Figure 8.
Figure 8: Browsing for FieldPoint I/O channels (or items or points)
[Table of contents]
5.3 Using OPC for I/O operations
OPC is short for OLE for Process Control which has become an important industry standard for connecting Windows programs (as LabVIEW) to I/O-equipment. All major automation vendors, as Siemens, National Instruments, Allen-Bradley, Honeywell etc., support OPC. (The home page of OPC is http://www.opcfoundation.org/ .)
The principle of OPC is as follows, cf. also the Figure 9.
- The OPC server of the I/O system (hardware) in use is assumed to be running. The OPC server is a service program running in the background of a PC. When using FieldPoint hardware the FieldPoint OPC server is automatically started as the FieldPoint Explorer is closed. The OPC server contains one item (or tag) for each of the channels configured in FieldPoint Explorer and the present value of the item.
- Any OPC client can read the value of an input item and can write a value to an output item on the OPC server. LabVIEW is one such OPC client.
Figure 9: The principle of OPC
OPC can be applied for I/O in LabVIEW either programmatically or menu based. The latter is the simpler.
Figure 10 shows the front panel and Figure 11 shows the block diagram ofiotest_opc.vi where the I/O operations are based on OPC.
Figure 10: Front panel ofiotest_opc.vi
Figure 11: Front panel ofiotest_opc.vi
The procedure for menu based OPC based I/O connection is described below.- Right-click on the terminal (in the block diagram) that is to be connected to the proper item on the OPC server. In Figure 10, this is either Control_signal or Measurement_signal. In the context menu opened, select Data operations / DataSocket Connection / Browse / Browse Measurement data.
Remember to select Publish if you want to write a value to the OPC server, and to select Subscribe if you want to read from the OPC server.
- Then browse to the proper item under the National Instruments.OPCFieldPoint OPC server. Typically items appear organised in groups. As an example, Figure 12 shows how to connect the Control_signal terminal (variable) to the Control item in the Analog Output group on the OPC server.
Figure 12: Connecting the Control_signal terminal (variable) to the Control item on the OPC server
As the VI runs the connection to the OPC server is indicated with a small rectangular lamp indicator at the upper right corner of the front panel element, see Figure 9. If the indicator is green the communication is ok. If it is red, something is wrong :-), and the error is displayed if you place the cursor over the indicator.
Additional information: FP2000 User Manual
October 28, 2005. Finn Haugen (finn@techteach.no).